V2_3D dataset of the X-ray Computed Tomography and plugin graph results

dc.contributor.authorChahid, Younes
dc.contributor.authorPacker, Chris
dc.contributor.authorTawfik, Ahmed
dc.contributor.authorKeen, Joel
dc.contributor.authorBrewster, Nick
dc.contributor.authorBeardsley, Mat
dc.contributor.authorMorris, Katherine
dc.contributor.authorBills, Paul
dc.contributor.authorBlunt, Liam
dc.contributor.authorAtkins, Carolyn
dc.contributor.authorTammas-Williams, Samuel
dc.date.accessioned2024-01-15T15:31:19Z
dc.date.available2024-01-15T15:31:19Z
dc.date.issued2023
dc.description.abstractV2: This dataset is an updated version of the previous Part 2/2 (http://dx.doi.org/10.5286/edata/901). This version includes updated Part 2.c graph outputs. Part 1/2: The first half of the dataset is composed of the Avizo plugin, which can be found in the DOI http://dx.doi.org/10.5286/edata/900 Part 2/2: This second half of the dataset is composed of the X-ray computed tomography data used in the study and their outputs. 2.a is composed of the XCT region of interest (ROI) showing the individual micro drilled holes, previously measured in the SEM. 2.b contains the isolated cube ROI used in the porosity analysis. 2.c contains the plugin graph outputs for each hole, when using the Avizo plugin. The XCT data in 2.a and 2.b is a subvolume of the full scan of an additive manufactured flexure containing a reference pin with micro drilled holes, measured in the scanning electron microscope (SEM). The scan settings included a voltage of 145 kV, filament current of 41 µA, number of projections of 1650 and a voxel size of 8.5 µm × 8.5 µm × 8.5 µm. After reconstruction, the scan was converted from 32 bit to 8-bit, aligned to the CAD and resampled, resulting in a voxel size change to 9.4 µm × 9.4 µm × 8.8 µm. Detailed use of the XCT scan dataset and resulting plugin graphs can be found in the study titled "Development of a modular system to provide confidence in porosity analysis of additively manufactured components using X-ray computed tomography".
dc.identifier.urihttps://edata.stfc.ac.uk/handle/edata/954
dc.identifier.urihttps://doi.org/10.5286/edata/922
dc.relation.ispartofhttp://dx.doi.org/10.5286/edata/900
dc.relation.isreferencedbyhttps://doi.org/10.1088/1361-6501/ad1670
dc.relation.isversionofhttp://dx.doi.org/10.5286/edata/901
dc.rightsCreative Commons Attribution 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleV2_3D dataset of the X-ray Computed Tomography and plugin graph results

Files

Original bundle

Now showing 1 - 2 of 2
No
Thumbnail
Available
Name:
V2_Part 2 XCT data and plugin outputs.zip
Size:
24.6 MB
Format:
ZIP file
No
Thumbnail
Available
Name:
V2_README for Part2.txt
Size:
1.76 KB
Format:
Plain Text

Collections